Toshiba e-STUDIO2500c Service Manual page 346

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2500c:
Table of Contents

Advertisement

(6)
Take off the pressure roller lamp and the
bearing from the pressure roller.
(7)
Remove the C-ring, and then take off the
gear and the bearing from the pressure
roller.
Note:
When installing the pressure roller, check if
the C-ring is securely engaged into the
groove of the pressure roller.
[A-8]
Separation plate / Fuser belt unit / Center heater lamp (LAMP1) / Side heater lamp
(LAMP2)
(1)
Take off the front side cover, pressure roller
cover and transport guide.
P.15-18 "[A-2] Front side cover"
P.15-18 "[A-4] Pressure roller cover"
P.15-19 "[A-5] Transport guide"
(2)
Loosen 2 pressure screws, and then remove
2 springs.
Note:
When installing, tighten the 2 pressure
screws securely until they are no longer
moved.
e-STUDIO2500c/3500c/3510c FUSER UNIT / PAPER EXIT SECTION
Pressure roller lamp
Bearing
Gear
C-ring
Spring
15 - 22
Pressure roller
Bearing
Fig. 15-23
Pressure roller
Fig. 15-24
Pressure screw
Fig. 15-25
May 2006 © TOSHIBA TEC