[ 2 ] Temperature detection section
[ 2-1 ]
Relation between the thermistor/thermopile output voltage and the surface temperature
of the fuser belt
Output voltages (V)
Fuser belt front thermistor
Approx. 0.3
Approx. 2.6
Approx. 3.6
[ 2-2 ]
Relation between the thermistor output voltage and the surface temperature of the
pressure roller
Output voltages (V)
Pressure roller center/
rear thermistor
Approx. 0.3
Approx. 1.2
Approx. 3.0
[ 2-3 ]
Surface temperature control for the fuser belt and pressure roller
Warming-up
°C
Temperature of fuser belt
Temperature of fuser belt
Temperature of fuser belt
160
130
0
Remark:
During warming-up before the pressure roller lamp is turned ON, the center and side heater
lamps are turned ON to raise the surface temperature of the fuser belt. When the pressure roller
lamp is ON, the equipment is in ready or printing status, each heater lamp is turned ON/OFF
alternately to maintain the surface temperature of the fuser belt at a certain level (setting temper-
ature of each status).
May 2006 © TOSHIBA TEC
Fuser belt center/
rear thermopile
Approx. 1.3
Approx. 1.9
Approx. 2.4
Surface temperatures of pressure roller (°C)
40
80
130
Ready ( 160°C )
Heater lamp
Heater lamp
Heater lamp
ON
OFF
ON
OFF ON OFF
Pressure roller lamp
Pressure roller lamp
Pressure roller lamp
ON
OFF
ON
OFF ON OFF
Temperature of pressure roller
Temperature of pressure roller
Temperature of pressure roller
Fig. 15-3
e-STUDIO2500c/3500c/3510c FUSER UNIT / PAPER EXIT SECTION
15 - 7
Surface temperatures of fuser belt (°C)
40
120
160
During printing ( 160°C )
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
15