Toshiba e-STUDIO2500c Service Manual page 156

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2500c:
Table of Contents

Advertisement

(3)
Detach the tension springs of the front and
rear sides.
(4)
Remove the carriage wires.
(5)
Rotate the carriage-2 in the direction where
the inside of the frame is dented shown in
the figure at right, not to touch the mirrors.
Then take off the carriage-2.
Notes:
1. When replacing the mirrors-2 and -3,
replace the carriage-2 together with mir-
rors-2 and -3. Mirrors-2 and -3 should not
be removed.
2. When installing carriage-2, fix the bracket
temporarily at the position (A). Then
move it to the direction (B), push it to the
end and fix securely.
(
P.6-25 "Fig. 6-36 ")
[J]
Platen sensor (S7) / Carriage home position sensor (S6)
(1)
Take off the upper rear cover.
P.2-35 "[Q] Upper rear cover"
(2)
Disconnect 1 connector. Release the latches
and take off the platen sensor.
(3)
Remove the seal.
(4)
Disconnect 1 connector. Release the latches
and take off the carriage home position sen-
sor.
e-STUDIO2500c/3500c/3510c SCANNER
Platen sensor
6 - 26
Fig. 6-39
Fig. 6-40
Carriage
home position sensor
Fig. 6-41
May 2006 © TOSHIBA TEC

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio3500cE-studio3510c

Table of Contents