Output Rf Spectrum (Orfs) - Agilent Technologies N9360A Programming Manual

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N O T E
N O T E

Output RF Spectrum (ORFS)

N9360A Multi UE Tester GSM Programming Manual
Incremental Redundancy
TESTs:MANual:INCRementalredundancy ON|OFF|0|1
TESTs:MANual:INCRementalredundancy?
This command sets the Incremental Redundancy in EGPRS
mode. At preset, this is set to 0.
This command is valid when the mode is set to EGPRS mode.
EVM Measurement Count
TESTs:MANual:EVMMeascount <int>
TESTs:MANual:EVMMeascount?
This command sets the EVM Meas. count in EGPRS mode. The
allowable range is from 1 to 200. At preset, this is set to 1.
This command is valid when the Modulation and Coding Scheme is set
from MCS5 to MCS9 in EGPRS mode except the Test Mode is set to ACK.
This query command returns the set EVM measurement count
with integer ranging from 1 to 200.
ORFS Modulation
TESTs:MANual:ORFS:MOD:STATe ON|OFF|0|1
TESTs:MANual:ORFS:MOD:STATe?
This command sets whether to execute each measurement item
of the ORFS Modulation. The parameter is ON (1) or OFF (0). At
preset, this is set to 1.
Programming Command Reference
5
5-159

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs8210

Table of Contents