N9360A Multi UE Tester GSM Programming Manual
Frequency Error Test
CONFigure:SEQuence:FREQuency <int>
CONFigure:SEQuence:FREQuency?
This command sets whether to execute the Frequency Error test
in the test sequence on the six measurement channels. <int>
sets whether to execute this test on each Traffic Channel by the
total sum of the 6 bits as follows.
bit 0 (1): Testing on the TCH1
bit 1 (2): Testing on the TCH2
bit 2 (4): Testing on the TCH3
bit 3 (8): Testing on the TCH4
bit 4 (16): Testing on the TCH5
bit 5 (32): Testing on the TCH6
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the Registers
The set of each bit is 1 for Run and 0 for — (skip). At preset, this
is set to 63.
This query command returns the set of Frequency Error test
with integer. The meaning of the return value is same as that of
the command parameter.
Programming Command Reference
on
page
4-18.