Programming Command Reference
5
5-128
Call Drop Timer
TESTs:MANual:CDTimer ON|OFF|1|0
TESTs:MANual:CDTimer?
This commands sets whether or not to use the Call Drop Timer.
The parameter is ON (1) or OFF (0). At preset, this is set to 1.
This is valid when Stand-by state and Connctio state
(Measuring state is excepted) of GSM mode and Stand-by state
and Attached state of GPRS and EGPRS mode.
Power Ramp Template
TESTs:MANual:TXP:MASK:PCS NARRow|RELaxed
TESTs:MANual:TXP:MASK:PCS?
This command sets template type of Power Ramp measuremnt
for PCS1900. The parameter is NARRow or RELaxed. At preset,
this is set to NARRow. If RELaxed is set, the template is selected
same one for DCS1800. This setting is initialized to NARRow at
power on.
IMSI control
TESTs:MANual:IMSI <string>
TESTs:MANual:IMSI?
This command sets the IMSI in Manual Test [Stand-by] screen.
The maximum digit of <string> is 15 and the range of a digit
is from 0 to 9. The value is set a value without double quotation.
Preset value is 001012345678901.
This query command returns IMSI.