Programming Command Reference
5
Caller ID
TESTs:AUTO:CALLer:ID <string>
TESTs:AUTO:CALLer:ID?
This command sets the Caller ID on the [Stand-by] screen.
<string>
Sets dialing number at BS call (AMR) test step. Up to 20 digit
arbitrary number (0 to 9) and symbol (*#) can be set. This is not
initialized by PRESET execution with the Starting Condition
softkey. At preset, this is set to 01234567890123456789.
This query command returns the set Caller ID with string.
Screen Mode
TESTs:AUTO:SCReen SIMPlified|DETailed|VALue
TESTs:AUTO:SCReen?
This command selects the screen mode. The parameter is
SIMPlified, DETailed, or VALue. At preset, this is set to
SIMPlified.
Query of this command returns the screen mode currently
selected in the character stings of the SIMPlified,
DETailed, or VALue.
Measurement TCH Variable
TESTs:AUTO:VARiable:TCH:CHANnel1 <int>
TESTs:AUTO:VARiable:TCH:CHANnel1?
TESTs:AUTO:VARiable:TCH:CHANnel2 <int>
TESTs:AUTO:VARiable:TCH:CHANnel2?
TESTs:AUTO:VARiable:TCH:CHANnel3 <int>
TESTs:AUTO:VARiable:TCH:CHANnel3?
N9360A Multi UE Tester GSM Programming Manual