Agilent Technologies N9360A Programming Manual page 227

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Programming Command Reference
5
Midamble
TXANalyzer:MIDamble <<
TSC0|TSC1|TSC2|TSC3|TSC4|TSC5|TSC6|TSC7|NONE
TXANalyzer:MIDamble?
This command selects a value of Training Sequence Code (TSC)
from TSC0 to TSC7 or NONE for the amplitude trigger. At preset,
this is set to TSC5.
This query command returns the selected value of Training
Sequence Code with strings.
Peak TX Power Mode
TXANalyzer:TXPower:STATe ON|OFF|1|0
TXANalyzer:TXPower:STATe?
This command sets whether to execute the Peak TX Power,
Burst Timing and Power Ramp test. The parameter is ON (1) or
OFF (0). At preset, this is set to 1.
This query command returns the set of the Peak TX Power test
with integer value of 1 or 0. The meaning of the return value is
same as that of the command parameter.
Phase Error/Frequency Error/EVM/Origin Offset Spr. Mode
TXANalyzer:PHASe:STATe ON|OFF|1|0
TXANalyzer:PHASe:STATe?
This command sets whether to execute the Phase Error,
Frequency Error, EVM and Origin Offset Spr. test. The
parameter is ON (1) or OFF (0). At preset, this is set to 1.
This query command returns the set of the Phase Error,
Frequency Error, EVM and Origin Offset Spr. test with integer
value of 1 or 0. The meaning of the return value is same as that
of the command parameter.