Agilent Technologies N9360A Programming Manual page 202

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Programming Command Reference
5
N O T E
5-144
• <int 3> (up to 7 letters) is the measured Frequency Error
data ranging from -99999.9 to 99999.9 (Hz) in 0.1 step. If
measurement result is out of measurement range or the
Frequency Error is not measured, the value 99999.9 is
returned.
RX Quality Measurement
TESTs:MANual:RESults:QUALity?
This query command returns the RX Quality measurement
values <int 1>, <int 2> and <int 3>. Each value is
separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the RX Quality is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <int 3> (1 digit) is the measured RX Quality factor ranging
from 0 (<0.2 %) to 7 (>12.8 %). If measurement result is out of
range or the RX Quality is not measured, the value 7 is
returned.
If the mode is set to GPRS or EGPRS, this query command is invalid.
Actual Timing Advance
TESTs:MANual:RESults:ACTAdvance?
This query command returns the actual Timing Advance with
integer value ranging from 0 to 63 in bits.
Origin Offset Spr. Measurement
TESTs:MANual:RESults:OOS?
This command returns the Origin Offset Spr. values <int 1>,
<int 2> and <real 3>. Each value is separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Origin Offset Spr. is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
N9360A Multi UE Tester GSM Programming Manual