N9360A Multi UE Tester GSM Programming Manual
Phase Error Marker Measurement
TESTs:AUTO:RESults:PHASe1:MARKer?
TESTs:AUTO:RESults:PHASe2:MARKer?
TESTs:AUTO:RESults:PHASe3:MARKer?
TESTs:AUTO:RESults:PHASe4:MARKer?
TESTs:AUTO:RESults:PHASe5:MARKer?
TESTs:AUTO:RESults:PHASe6:MARKer?
These query commands return values at marker position on the
Phase Error graph screen with values <int 1>, <int 2>,
<real 3> and <real 4> for each of the six measurement
channels. Each value is separated by a comma.
• <int 1> (1 digit) is 0 if measurement results are within the
measurement range, or 1 if value is out of range or the Phase
Error is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> (up to 6 letters) is the marker position ranging
from 0.00 to 147.00 in bits.
• <real 4> (up to 5 letters) is the measured phase error at
the marker position. If any measurement result is out of
range or the Phase Error is not measured, the value 99.9 is
returned.
Programming Command Reference
5
5-105