5
N O T E
5-142
EVM Measurement
TESTs:MANual:RESults:EVM?
This command returns the EVM test result values <int 1>,
<int 2>, <int 3>, <int 4> and <int 5>. Each value is
separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Burst Timing is not measured.
• <int 2> (1 digit) contains test results by the total sums of 3
bits as follows. When measurement result is out of range, or
the EVM was not measured, the value 99.99 is returned.
bit 0 (1): Pass or Fail result for EVM RMS
bit 1 (2): Pass or Fail result for EVM Peak
bit 2 (4): Pass or Fail results for EVM 95 %
• <real 3>, <real 4>, and <real5> (4 letters) is the
measured data of RMS, PEAK, and 95 % of EVM, respectively.
The data is ranging from 0.00 to 100.00 (%). If
measurement result is out of range or the EVM is not
measured, the value 99.99 is returned.
This command is valid when Modulation and Coding Scheme is set to
MCS5 to MCS9 in EGPRS mode.
Phase Error Measurement
TESTs:MANual:RESults:PHASe?
This query command returns the Phase Error measurement
result values <int 1>, <int 2>, <real 3> and <real 4>.
Each value is separated by a comma.
• <int 1> (1 digit) is 0 when if measurement results are
within the measurement range, or 1 if any measurement
result is out of range or the Phase Error is not measured.
• <int 2> (1 digit) contains test results by sum of value of 2
bits as follows.
bit 0 (1): Pass or Fail result for RMS Phase Error
bit 1 (2): Pass or Fail result for Peak Phase Error