Programming Command Reference
5
5-168
Power Control Level
TXANalyzer:PLEVel <int>
TXANalyzer:PLEVel?
This command sets a value of Power Control Level for each
radio system set by the
page
5-166. The allowable range and preset values are as
follows:
Table 5-44 Power Control Level Allowable Range and Preset Value
RFORmat
Allowable Range [Hz]
GSM850
2 (+39 dBm) to 19 (+5 dBm)
GSM900
2 (+39 dBm) to 19 (+5 dBm)
DCS1800
0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
PCS1900
0 (+30 dBm) to 15 (+0 dBm), or
30 (+33 dBm) to 31 (+32 dBm)
Amplitude
TXANalyzer:AMPLitude <real>
TXANalyzer:AMPLitude?
This command sets the amplitude of output signal from the
Tester applied to the mobile phone under test. The allowable
range is from -110.0 to -20.0 (dBm) in 0.1 steps. At preset,
this is set to -50.0 (dBm).
This query command returns the set amplitude of output signal
by real ranging from -110.0 to -20.0 (dBm).
MS Signal
TXANalyzer:SIGNal BURST|CW
TXANalyzer:SIGNal?
This command selects a signaling type from the mobile phone
for analysis. The parameter is BURST or CW. At preset, this is set
to BURST.
This query command returns the selected signal type with
strings of BURST or CW.
Radio System
command described on
N9360A Multi UE Tester GSM Programming Manual
Preset Value [Hz]
5 (+33 dBm)
5 (+33 dBm)
0 (+30 dBm)
0 (+30 dBm)