Spectrum Monitor Screens; Table 6-27 Tx Analyzer Smonitor Command Summary - Agilent Technologies N9360A Programming Manual

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Programming Command Summary
6
Table 6-26 ORFS Command Summary
Item
ORFS Modulation Measurement
ORFS Switching Measurement
Ref. Power

Spectrum Monitor Screens

Table 6-27 TX Analyzer SMONitor Command Summary

Item
Span
Resolution Bandwidth
Spectrum Measurement
Spectrum Marker Measurement
Spectrum Marker Position Control
6-40
Command
TXAN:RES:ORFS:MOD?
TXAN:RES:ORFS:SW?
TXAN:RES:ORFS:P?
The following commands are used to set the controls and
parameters associated with the screens for Spectrum Monitor
measurement and to get measurement Pass/Fail test results.
Command
TXAN:SMON:SPAN 400K|100K
TXAN:SMON:SPAN?
TXAN:SMON:RBW 10K|30K
TXAN:SMON:RBW?
TXAN:RES:SMON?
TXAN:RES:SMON:MARK?
TXAN:RES:SMON:MARK:POIN UP|DOWN
TXAN:RES:SMON:MARK:POIN <real>
TXAN:RES:SMON:MARK:POIN?
N9360A Multi UE Tester GSM Programming Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs8210

Table of Contents