• <real 3> (up to 6 letters) is the measured Origin Offset Spr.
data ranging from 0.0 to 99.9.
This command is valid when the Modulation and Coding Scheme is set
from MCS5 to MCS9 in EGPRS mode.
EVM Marker
TESTs:MANual:RESults:EVM:MARKer?
This command returns the EVM Marker value <int1>, <int2>,
<real3> and <real4>.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the EVM Marker is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> returns Marker position (bits).
• <real 4> (up to 6 letters) is the measured EVM Marker data
ranging from 0.00 to 100.00 (%).
This command is valid when the Modulation and Coding Scheme is set
from MCS5 to MCS9 in EGPRS mode.
EVM Marker Point
TESTs:MANual:RESults:EVM:MARKer:POINt UP|Down
TESTs:MANual:RESults:EVM:MARKer:POINt <real>
This command moves the marker position Up or Down in steps,
or by <real> bits ranging from 0.00 to 423.00 in bits.
This command is valid when the Modulation and Coding Scheme is set
from MCS5 to MCS9 in EGPRS mode.