Agilent Technologies N9360A Programming Manual page 241

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N O T E
N O T E
N9360A Multi UE Tester GSM Programming Manual
EVM Measurement
TXANalyzer:RESults:EVM?
This command returns the EVM test result values <int1>,
<int2>, <real3>, <real4>, <real5>. Each value is separated
by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Burst Timing is not measured.
• <int 2> (1 digit) contains test results by the total sums of 3
bits as follows.
bit 0 (1): Pass or Fail result for EVM RMS
bit 1 (2): Pass or Fail result for EVM Peak
bit 2 (4): Pass or Fail results for EVM 95%
• <real 3>, <real 4>, <real 5> returns the measurement
result value of RMS, Peak, and 95 % respectively. When
measurement result is out of range, or the EVM was not
measured, the value 99.99 is returned.
This command is valid when the Demodulation is set to 8-PSK.
Installation of the Option G03 is required.
EVM Marker
TXANalyzer:RESults:EVM:MARKer?
This command returns the EVM Marker value <int1>, <int2>,
<real3> and <real4>.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the EVM Marker is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> returns Marker position (bits).
• <real 4> (up to 6 letters) is the measured EVM Marker data
ranging from 0.00 to 99.99 (%).
This command is valid when the Demodulation is set to 8-PSK.
Installation of the Option G03 is required.
Programming Command Reference
5
5-183

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs8210

Table of Contents