Agilent Technologies N9360A Programming Manual page 114

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Programming Command Reference
5
5-56
2nd Call Type
CONFigure:SEQuence:SIGNaling:CALL2:TYPE MS|BS
CONFigure:SEQuence:SIGNaling:CALL2:TYPE?
This command sets the second caller at the sixth test flow step.
The parameter is MS or BS. At preset, this is set to BS.
This query command returns the set of second caller with string
of MS or BS. The meaning of the return value is same as that of
the command parameter.
2nd Call Test
CONFigure:SEQuence:SIGNaling:CALL2 ON|OFF|1|0
CONFigure:SEQuence:SIGNaling:CALL2?
This command sets whether to execute the second call in a test
flow. The parameter is ON (1) for Run or OFF (0) for — (skip). At
preset, this is set to 1.
This query command returns the set of second call test with
integer value of 1 or 0. The meaning of the return value is same
as that of the command parameter.
2nd Release Type
CONFigure:SEQuence:SIGNaling:REL2:TYPE MS|BS
CONFigure:SEQuence:SIGNaling:REL2:TYPE?
This command sets the second caller at the sixth test flow step.
The parameter is MS or BS. At preset, this is set to BS.
This query command returns the set of second caller with string
of MS or BS. The meaning of the return value is same as that of
the command parameter.
N9360A Multi UE Tester GSM Programming Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs8210