N9360A Multi UE Tester GSM Programming Manual
Frequency Error Measurement
TESTs:AUTO:RESults:FREQuency1?
TESTs:AUTO:RESults:FREQuency2?
TESTs:AUTO:RESults:FREQuency3?
TESTs:AUTO:RESults:FREQuency4?
TESTs:AUTO:RESults:FREQuency5?
TESTs:AUTO:RESults:FREQuency6?
These query commands return the Frequency Error
measurement result values <int 1>, <int 2> and <real 3>
for each of the six measurement channels. Each value is
separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Frequency Error is not measured.
• <int 2> (1 digit) is the test result for the pass (0) or fail (1).
• <real 3> (up to 5 letters) is the measured Frequency Error
data ranging from -99999 to 99999 (Hz). If measurement
result is out of range or the Frequency Error is not
measured, the value 99999 is returned.
This command is a command for compatibility with the former,
and returns measured value by the resolution of a 1Hz unit.
Since a following EXPand command can return in finer
resolution, and it is recommendation to use it.
TESTs:AUTO:RESults:FREQuency1:EXPand?
TESTs:AUTO:RESults:FREQuency2:EXPand?
TESTs:AUTO:RESults:FREQuency3:EXPand?
TESTs:AUTO:RESults:FREQuency4:EXPand?
TESTs:AUTO:RESults:FREQuency5:EXPand?
TESTs:AUTO:RESults:FREQuency6:EXPand?
These query commands return the Frequency Error
measurement result values <int 1>, <int 2> and <real 3>
for each of the six measurement channels. Each value is
separated by a comma.
Programming Command Reference