Programming Command Reference
5
N O T E
N O T E
5-182
Phase Error Marker Measurement
TXANalyzer:RESults:PHASe:MARKer?
This query command returns values at marker position on the
Phase Error graph screen by values <int 1>, <int 2>, <real
3> and <real 4>. Each value is separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Phase Error is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> (up to 6 letters) is the marker position ranging
from 0.00 to 147.00 in bits.
• <real 4> (up to 5 letters) is the measured Phase Error at
marker position. If measurement result is out of range or the
Phase Error is not measured, the value 99.9 is returned.
This command is valid when Demodulation is set to GMSK.
Phase Error Marker Position Control
TXANalyzer:RESults:PHASe:MARKer:POINt UP|DOWM
TXANalyzer:RESults:PHASe:MARKer:POINt <real>
TXANalyzer:RESults:PHASe:MARKer:POINt?
This command moves the marker UP or DOWN in steps, or by
<real> ranging from 0.00 to 147.00 in bits, in the Phase Error
graph for each of the six measurements.
This command is valid when Demodulation is set to GMSK.
N9360A Multi UE Tester GSM Programming Manual