Command Reference for Measurement Screen

N9360A Multi UE Tester GSM Programming Manual
Peak TX Power Measurement
TESTs:MANual:RESults:TXPower?
This query command returns the Peak TX Power measurement
result values <int 1>, <int 2> and <real 3>. Each value is
separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Peak TX Power is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> (up to 5 letters) is the measured data ranging
from -99.9 to 99.9 in dBm. If measurement result is out of
range or the Peak TX Power is not measured, the value
-99.9 is returned.
Burst Timing Measurement
TESTs:MANual:RESults:BTIMing?
This query command returns the Burst Timing measurement
result values <int 1>, <int 2> and <real 3>. Each value is
separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Burst Timing is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> (4 letters) is the measured data ranging from
-9.9 to 9.9 in bits. If measurement result is out of range or
the Burst Timing is not measured, the value -9.9 is
returned.
Power Ramp Measurement
TESTs:MANual:RESults:RAMP?
This query command returns the Power Ramp measurement
result values <int 1> and <int 2>. Each value is separated by
a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the Power Ramp is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).