Agilent Technologies N9360A Programming Manual page 311

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Table 7-5 Program Comments
Line
Description
2:
Declares the variable to store test results.
4:
Erases the status field.
N9360A Multi UE Tester GSM Programming Manual
27
: WAIT "TEST:MAN:SIGN:STAT?", 2
28
:
29
:'Peak TX Power
30
: OUTPUT "DISP:MAN:TPOW"
31
: OUTPUT "TRIG:IMM"
32
: WAIT "*STB?", 0
33
: value = Split(ENTER("TEST:MAN:RES:TXP?"),
",")
34
: AddStatus "Peak TX Power
"dBm " + IIf(value(1) And 1, "FAIL", "PASS")
35
:
36
:'Phase Error & Freq Error
37
: OUTPUT "DISP:MAN:PHAS"
38
: OUTPUT "TRIG:IMM"
39
: WAIT "*STB?", 0
40
: value = Split(ENTER("TEST:MAN:RES:PHAS?"),
",")
41
: AddStatus "Phase Err rms
"deg " + IIf(value(1) And 1, "FAIL", "PASS")
42
: AddStatus "Phase Err peak
"deg " + IIf(value(1) And 2, "FAIL", "PASS")
43
: value = Split(ENTER("TEST:MAN:RES:FREQ?"),
",")
44
: AddStatus "Frequency Error : " + value(2) +
"Hz " + IIf(value(1) And 1, "FAIL", "PASS")
45
:
46
:' BS Release
47
: OUTPUT "TEST:MAN:BSR"
48
:
49
: AddStatus "Complete"
50
: End Sub
Sample Program
:" + value(2) +
: " + value(2) +
: " + value(3) +
7-11
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs8210

Table of Contents