Download Print this page

Agilent Technologies Infi niium 9000 Series Quick Demo Manual

Advertisement

Quick Links

Infiniium 9000 Series
Engineered for the broadest
measurement capability.
Designed to fi t your environment
• Biggest screen in class (15" XGA)
• Touchscreen with 1024x768
resolution
• Thin
• Light (26 lbs)
• Knob per channel
• Convenient USB and other
connectivity
• Quiet fans (30 db in front)
3 instruments in 1 box
Scope: Powerful Infi niium features
coupled with superior specs for
precise signal representation.
Logic analyzer: 16 fully integrated
digital channels to see critical data
values and timing relationships
Protocol analyzer: World's fi rst
scope-based protocol viewer with
multi-tab viewing to quickly drill down
and move between protocol and
physical layers.
Widest range of debug and
compliance apps:
Tailor your
scope to simplify debug and
compliance testing today and
in the future with the industry's
widest range of application software.
The Infi niium 9000 Series
Oscilloscope Quick Demo
9000 Series demo board, mouse and two passive probes required
Oscilloscope Demonstration
600 MHz, 1 GHz, 2.5 GHz, 4 GHz Models • 20 Mpts – 1 Gpt Memory • 10- 20 GSa/s
Quick demo
1. Press Default Setup.
2. Press AutoScale.
3. Adjust timebase to about 10 us/div
and delay to get the following display of
USB signals.
4. Drag and drop the rise time measurement
icon onto the signal to demonstrate quick
measurements.
5. Expand the measurement tab window.
Highlight the Measure menu at the top of
the screen to illuminate the drop
down menus and walk through some of
the measurements Infi niium
Connect channel 1 probe to red test point
marked D+ and corresponding ground,
connect channel 2 probe to red test point
marked D- and corresponding ground.
Mouse signal is passed through and
acquired by scope. Move mouse and see
transmission of USB packets with XY
coordinates.
6. Highlight the Analyze menu at the top
of the screen to show rich feature set
here also.
7. Highlight the Trigger menu at the top
of the screen, click on setup trigger and
point out trigger shortcuts and gallery.
8. Then choose Infi niiScan and select
Zone Qualify from the menu. Draw a box
around area where signals occur when
you move the mouse and select AND
Must Intersect from the Zone 1 menu
choice. Powerful hardware triggering
combined with Infi niiScan event triggering
makes for effi cient troubleshooting.
9. Highlight the Setup tab at the top of the
screen and select Acquisition. Change
the Analog Memory Depth setting to
Manual and select Max. Close the setup
screen and adjust the timebase to about
1 ms/div to show multiple bursts on
screen.
10. Press the zoom button to see detail
for one of the bursts. Responsive deep
memory allows you to take advantage of
your investment to zero in on the details
when needed.

Advertisement

loading

Summary of Contents for Agilent Technologies Infi niium 9000 Series

  • Page 1 The Infi niium 9000 Series Oscilloscope Quick Demo 9000 Series demo board, mouse and two passive probes required Infiniium 9000 Series Connect channel 1 probe to red test point marked D+ and corresponding ground, Engineered for the broadest connect channel 2 probe to red test point measurement capability.
  • Page 2 Protocol Analyzer Demonstration Mixed-Signal Oscilloscope (Logic Analyzer) Demonstration For more information on Agilent Technologies’ products, applications or services, please Time-aligned physical and protocol views • Broadest support available •Industry’s only 16 integrated, time-aligned contact your local Agilent office. The...