Agilent Technologies N9360A Programming Manual page 126

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Programming Command Reference
5
N O T E
N O T E
5-68
Test Loop Mode
CONFigure:CONDition:TESTLoopmode:GSM A|C
CONFigure:CONDition:TESTLoopmode:GSM?
CONFigure:CONDition:TESTLoopmode:GPRS ACK|A|B
CONFigure:CONDition:TESTLoopmode:GPRS?
CONFigure:CONDition:TESTLoopmode:EGPRS
ACK|A|B|SRB
CONFigure:CONDition:TESTLoopmode:EGPRS?
This command sets the Test Loop Mode of GSM, GPRS, and
EGPRS. The allowable selection is A and C for GSM, ACK, A and
B for GPRS, and ACK, A, B and SRB for EGPRS. At preset, GSM
mode is set to A, and GPRS and EGPRS mode is set to ACK.
The above commands are valid only for corresponding mode setting
(GSM, GPRS and EGPRS).
Connection Wait Time
CONFigure:CONDition:CONnectionwait <int>
CONFigure:CONDition:CONnectionwait?
This command sets Connection Wait Time of MS Call. The
allowable range is from 0 to 120. At preset, this is set to 0.
This command is valid when the GSM mode is set to GSM.
Power Control Level (Limit)
CONFigure:CONDition:LIMit:TXPower:PLEVel <int>
CONFigure:CONDition:LIMit:TXPower:PLEVel?
This command sets the value of Peak TX Power for each radio
system set by the
Radio System
page
5-34.
command described on
N9360A Multi UE Tester GSM Programming Manual