Agilent Technologies N9360A Programming Manual page 69

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N9360A Multi UE Tester GSM Programming Manual
Autoboot
CONFigure:AUTOBoot NONE|GSM|WCDMA|CDMA2000,
<int>
CONFigure:AUTOBoot?
This command selects AUTOBoot setting from NONE, GSM,
WCDMA and CDMA2000, that is automatically activated in a
certain period of time after the Menu screen is displayed, and
<int> sets the duration time (unit: second) until start of
automatic boot.
• If this is set to NONE, the Tester will not automatically start.
• If this is set to GSM, WCDMA, or CDMA2000, the Tester will
automatically start the GSM application, the W-CDMA
application, or the cdma2000 application respectively.
• G00 option is required to install in the Tester to boot GSM.
• W00 option is required to install in the Tester to boot
WCDMA.
• C00 and C01 options are required to install in the Tester to
boot cdma2000.
The duration time is within the ranges from 10 to 60 seconds in
1 steps. At preset, these settings are NONE and 10, which means
the Tester does not start automatic boot and the display shows
the [Top menu] screen.
If 0 is set other than NONE, an execution error occurs.
This query command returns the settings of application name
and the duration time. When this command is set to NONE, it
returns 0.
RF-CPU Revision
CONFigure:REVision:RF?
This query command returns the firmware revision of RF-CPU
with a string xx.xx.