Command Reference For Test Result (Signaling And Rf Test) - Agilent Technologies N9360A Programming Manual

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Command Reference for Test Result (Signaling and RF Test)

N9360A Multi UE Tester W-CDMA Programming Manual
Talk Test Result
TESTs:AUTO:MEASure:TALK PASS|FAIL
This command sets the test result of the Talk test step to pass or
fail. The parameter is
Signaling State
TESTs:AUTO:MEASure:SIGNaling:STATe?
This query command returns the test step currently executed in
a test cycle. The return value contains the currently executed
status of 12 bits as follows.
bit 0(1): Location Update
bit 1(2): MS Call
bit 2(4): Talk
bit 3(8): MS Release
bit 4(16): BS Call(AMR)
bit 5(32): Talk
bit 6(64): BS Release
bit 7(128): BS Call(RMC)
bit 8(256):RF Test
bit 9(512): BS Release
bit 10(1024): Measurement end with test result
bit 11(2048): Measurement end without test result
(Aborted or Time out error occurred)
The executed step is set to
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the Registers
The following query commands return the test results.
Programming Command Reference
or
.
PASS
FAIL
, and the others are set to
1
on
page
5
.
0
14.
5-41