Programming Command Reference
5
Transmit Data
CONFigure:CONDition:DATA PN9FIX|PN9|PN15
CONFigure:CONDition:DATA?
This command selects a type of TCH mapping data. The
parameter is PN9FIX, PN9 or PN15. At preset, this is set to
PN15.
This query command returns the set type of TCH mapping data
with strings of PN9FIX, PN9 or PN15.
Averaging
CONFigure:CONDition:AVERage OFF|2-200
CONFigure:CONDition:AVERage?
This command selects whether to activate the Averaging. The
parameter is OFF or <int> for the number of averaging times.
The allowable range of <int> is from 2 to 200. At preset, this is
set to OFF.
This query command returns the set averaging.
BS Level
CONFigure:CONDition:AMPLitude <real>
CONFigure:CONDition:AMPLitude?
This command sets the amplitude (BS Level) of the output
signal from the Tester. The allowable range is from -110.0 to
-50.0 dBm in 0.1 steps. At preset, this is set to -50.0 dBm.
This query command returns the set amplitude of output signal
with real. The range of the value is same as that of the command
parameter.