Programming Command Reference
5
N O T E
N O T E
5-140
• <int 2> (1 digit) is the measured RX Quality data ranging
from 0 to 7 bits. If measurement result is out of range or the
RX Quality is not measured, the value 7 is returned.
A different command should be used to obtain RX Quality during
Sensitivity measurement.
The value is not returned in the GPRS and EGPRS mode.
TESTs:MANual:RESults:MSINformation:LEVel?
This query command returns a value of RX Level.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or the RX Level is not measured.
• <int 2> (1 or 2 digits) is the measured RX Level data
ranging from 0 to 63 bits. If measurement result is out of
range or the RX Level is not measured, the value 63 is
returned.
A different command should be used to obtain RX Level during Sensitivity
measurement.
The value is not returned in the GPRS and EGPRS mode.
Multislot Class
TESTs:MANual:RESults:MSINformation:MULTislotclas
s?
This query command returns the value of Multislot class. <int
1> is for GPRS, <int 2> is for EGPRS. In the GPRS mode, <int
2> is set to 0.
RF Power Capability
TESTs:MANual:RESults:MSINformation:RFPowercapabi
lity?
This query command returns the value of RF Power. From
<int1> to <int8> in sequence, the value of GMSK/GSM850,
GSMK/GSM900, GSMK/DCS1800, GSMK/PCS1900,
8-PSK/GSM850, 8-PSK/GSM900, 8-PSK/DCS1800 and
8-PSK/PCS1900 are assigned. Each value is separated by a
comma.