Table 5-12 Power Control Level Allowable Range and Preset Value

RFORmat
Allowable Range
GSM850
2 (+39 dBm) to 19 (+5 dBm)
GSM900
2 (+39 dBm) to 19 (+5 dBm)
DCS1800
29 (+36 dBm) to 31 (+32 dBm), 0 (+30 dBm) to 15 (+0 dBm)
PCS1900
30 (+33 dBm) to 31 (+32 dBm), 0 (+30 dBm) to 15 (+0 dBm)

Table 5-13 Power Control Level Allowable Range and Preset Value

RFORmat
Allowable Range
GSM850
2 (+39 dBm) to 19 (+5 dBm)
GSM900
2 (+39 dBm) to 19 (+5 dBm)
DCS1800
0 (+30 dBm) to 15 (+0 dBm), or 29 (+36 dBm) to 31 (+32 dBm)
PCS1900
0 (+30 dBm) to 15 (+0 dBm), or 30 (+33 dBm) to 31 (+32 dBm)
N9360A Multi UE Tester GSM Programming Manual
This query command returns the set value of Peak TX Power
with integer. The range of the value is same as that of the
command parameter.
Peak TX Power Limit
CONFigure:CONDition:LIMit:TXPower <int
PLEV>,<real LO>,<real HI>
CONFigure:CONDition:LIMit:TXPower?
This command sets a value of Power Control Level (PWR CNTL)
and the low and high limits for Peak TX Power tests, for each
radio system set by the
page
5-34. The power control level and the preset values are as
follows. The allowable limit range for <real LO> and <real
HI> is from -99.9 to 99.9 dB in 0.1 steps. At preset, these are
set to -3.0 and 3.0 dB.
This query command returns the set power control level with
integer and low and high limits for Peak TX Power test with real
separated by a comma. The range is same as that of the
command parameter.
Programming Command Reference
Radio System
command described on
5
Preset Value
5 (+29 dBm)
5 (+29 dBm)
0 (+30 dBm)
0 (+30 dBm)
Preset Value
5 (+33 dBm)
5 (+33 dBm)
0 (+30 dBm)
0 (+30 dBm)
5-69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs8210