Averaging
TXANalyzer:AVERage OFF|2-200
TXANalyzer:AVERage?
This command sets whether to activate the averaging. The
parameter is OFF or <int> for the number of averaging times.
The allowable range of <int> is from 2 to 200. At preset, this is
set to OFF.
This query command returns the set averaging.
Modulation
TXANalyzer:MODulation <<
BCCH|PN9|PN15|ALL0|ALL1|AM|PSK9|PSK15
TXANalyzer:MODulation?
This command sets a type of Modulation for the Signal
Generator. The parameter for GMSK is BCCH, PN9, PN15, ALL0,
and ALL1, while the parameter for 8-PSK is PSK9 and PSK15. At
preset, this is set to BCCH.
Demodulation
TXANalyzer:DEMODulation GMSK|PSK
TXANalyzer:DEMODulation?
This command sets demodulation of the Tester. The parameter
is GMSK or PSK (8-PSK). At preset, this is set to GMSK.
Frequency Offset
TXANalyzer:OFFSet <int>
TXANalyzer:OFFSet?
This command sets the frequency offset. The allowable range is
from -100.0 to 100.0 kHz in 0.1 steps. At preset, this is set to
0.0 (kHz).