Polycom RMX 1500 Administrator's Manual page 560

Multipoint control unit
Hide thumbs Also See for RMX 1500:
Table of Contents

Advertisement

Polycom RMX 1500/2000/4000 Administrator's Guide
9
10 Define the following parameters:
19-68
Click the Traps tab.
The RMX-SNMP Properties – Traps dialog box opens.
Traps are messages sent by the MCU to the SNMP Managers when events such as MCU
Startup or Shutdown occur. Traps may be sent to several SNMP Managers whose IP
addresses are specified in the Trap Destinations box.
Table 19-20
SNMPv3 - Traps
Field
SNMP Trap Version
Specifies the version, either Version1 2 or 3 of the traps being sent to
the IP Host. Polycom software supports the standard SNMP version 1
and 2 traps, which are taken from RFC 1215, convention for defining
traps for use with SNMP.
Note: The SNMP Trap Version parameters must be defined
identically in the external SNMP application.
Version 3
Versions 1 & 2
Description
Polycom, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmx 4000Rmx 2000

Table of Contents