Table 19-2
System Flags – MCMS_PARAMETERS (Continued)
Flag
_SPEAKER_INTRA_SUPPR
ESSION_IN_SECONDS
CPU_TCP_KEEP_ALIVE_TI
ME_SECONDS
CPU_TCP_KEEP_INTERVAL
_SECONDS
DISABLE_INACTIVE_USER
ENABLE_CYCLIC_FILE_SY
STEM_ALARMS
ENABLE_EXTERNAL_DB_A
CCESS
ENABLE_AUTO_EXTENSIO
N
ENABLE_CASCADED_LINK
_TO_JOIN_WITHOUT_PASS
WORD
Description
This flag controls the requests to refresh (intra) the sent from
the RMX system to the sender as a result of refresh requests
initiated by other conference participants.
Enter the interval in seconds between the Intra requests sent
from the RMX to the endpoint sending the to refresh the
display. Refresh requests that will be received from endpoints
within the defined interval will be postponed to the next
interval.
Default setting: 5
This flag indicates when to send the first KeepAlive indication
to check the TCP connection.
Default value: 7200 second (120 minutes)
Range: 600-18000 seconds
When there are NAT problems, this default may be too long
and the TCP connection is lost. In such a case, the default
value should be changed to 3600 seconds (60 minutes) or
less.
This flag indicates the interval in seconds between the
KeepAlive requests.
Default value: 75 second
Range: 10-720 seconds.
Users can be automatically disabled by the system when they
do not log into the RMX application for a predefined period.
Possible Values: 0 - 90 days.
Default: 0 (disables this option).
Default (ULTRA_SECURE_MODE=YES): 30
Enables or disables the display of Active Alarms before
overwriting the older CDR/Auditor/Log files, enabling the
users to backup the older files before they are deleted.
Default: NO
Default (ULTRA_SECURE_MODE=YES): YES
If YES, the RMX connects to an external database
application, to validate the participant's right to start a new
conference or access a conference.
Default: NO
Allow conferences running on the RMX to be automatically
extended as long as there are participants connected.
Default: YES
Enables a cascaded link to enter a conference without a
password.
Default: NO, for security reasons.
Polycom, Inc.
Need help?
Do you have a question about the RMX 1500 and is the answer not in the manual?
Questions and answers