Polycom RMX 1500/2000/4000 Administrator's Guide
To enable Lecture Mode for the Conference:
>> In the Conference Properties - Participant dialog box, select the Lecturer from the list.

Restricting Content Broadcast to Lecturer

Content broadcasting can be restricted to the conference lecturer only, when one of the
conference participants is set as the lecturer (and not automatically selected by the system).
Restricting the Content Broadcast prevents the accidental interruption or termination of
H.239 Content that is being shared in a conference.
Content Broadcast restriction is enabled by setting the
RESTRICT_CONTENT_BROADCAST_TO_LECTURER system flag to ON. When set to
OFF (default) it enables all users to send Content.
When enabled, the following rules apply:

Content Broadcast Control

Content Broadcast Control prevents the accidental interruption or termination of H.239
Content that is being shared in a conference.
2-76
Content can only be sent by the designated lecturer. When any other participant tries to
send Content, the request is rejected.
If the RMX user changes the designated lecturer (in the Conference Properties - Video
Settings dialog box), the Content of the current lecturer is stopped immediately and
cannot be renewed.
The RMX User can abort the H.239 Session of the lecturer.
Content Broadcasting is not implemented in conferences that do not include a
designated lecturer and the lecturer is automatically selected by the system (for
example, in Presentation Mode).