RMON Alarm Configuration

Clicking the A
LARM
which configures RMON Alarm paramters. The parameters for this page are shown in
Table
7-26.

Table 7-26. RMON Alarm Configuration Page Parameters

Parameter
Index
Interval
Variable
Sample Type
Rising Threshold
Falling Threshold
Rising Event Index
Chapter 7: Layer 2/3 Ethernet Switch Firmware

Figure 7-38. RMON Alarm Configuration Page

tab brings up the RMON A
Description
This parameter specifies the table index.
This parameter specifies the time interval for which the alarm monitors the
variable.
This parameter specifies the MIB object on which the alarm is set.
You can set this parameter to an Absolute Value or as just an Incremental
Value of the timer.
If the startup alarm is set as Rising Alarm and this threshold is reached, an
alarm is raised.
If the startup alarm is set as Falling Alarm and this threshold is reached, an
alarm is raised.
Indicates the index of the event to be raised when the R
reached.
C
LARM
ONFIGURATION
7-45
page
(Figure
7-38),
T
is
ISING
HRESHOLD