Installing The Ids-4210 - Cisco IDS-4230-FE - Intrusion Detection Sys Fast Ethernet Sensor Installation And Configuration Manual

Intrusion detection system appliance and module
Table of Contents

Advertisement

Chapter 2

Installing the IDS-4210

Step 9
Step 10
Step 11
Installing the IDS-4210
Warning
Caution
Note
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Install the new DIMM (one at a time if you are installing more than one), by
positioning the DIMM into the socket and pressing it into place.
Do not force the DIMM into the socket. Alignment keys on the DIMM
Note
ensure that it only fits in the socket one way. If you need additional
leverage, you can gently press down on the DIMM with your thumbs
while pulling up on the ejector tabs.
Replace the chassis cover and reconnect the power.
Power on the sensor and ensure the new memory total is correct.
If the memory total does not reflect the added DIMMs, repeat Steps 1
Note
through 4 to ensure the DIMMs are seated correctly in the socket.
Only trained and qualified personnel should be allowed to install, replace, or
service this equipment. Statement 1030
Be sure to read the safety warnings in the Regulatory Compliance and Safety
Information for the Cisco Intrusion Detection System 4200 Series Appliance
Sensor and follow proper safety procedures when performing these steps.
If you purchased an IDS-4210 before July 2003, you must upgrade the memory to
256 MB to install Cisco IDS 4.1. See
information. If you purchase an IDS-4210 during July, it comes from the factory
with the memory upgrade and version 4.1 installed.
Upgrading the Memory, page
Installing the IDS-4210
2-3, for more
2-5