Cisco IDS-4230-FE - Intrusion Detection Sys Fast Ethernet Sensor Installation And Configuration Manual page 296

Intrusion detection system appliance and module
Table of Contents

Advertisement

IDSM-2 Configuration Tasks
Step 1
Step 2
Step 3
Cisco IOS Software
Step 1
Step 2
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
10-100
To enable a full memory test, follow these steps:
Log in to the console.
Type the following commands:
Console> set boot device cf:1 4
mem-test-full
Console> show boot device 4
The set boot device command can either contain cf:1 or hdd:1.
The following output appears:
Device BOOT variable = cf:1
FAST BOOT Enabled
Reset the IDSM-2.
See
Resetting the IDSM-2, page
The full memory test runs.
A full memory test takes more time to complete than a partial memory
Note
test.
You can enable a full memory test when you use the set boot device bootseq
module_number mem-test-full command. The long memory test takes about 12
minutes.
To enable a full memory test, follow these steps:
Log in to the console.
Type the following commands:
Router# set boot device cf:1 4 mem-test-full
Router# show boot device 4
The set boot device command can either contain cf:1 or hdd:1.
Chapter 10
Configuring the Sensor Using the CLI
10-101, for the procedure.
78-15597-02

Advertisement

Table of Contents
loading

Table of Contents