Chapter 10
Configuring the Sensor Using the CLI
Step 12
Step 13
Step 14
Disabling IP Logging
Step 1
Step 2
Step 3
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Exit Virtual Sensor Configuration mode:
sensor(config-vsc)# exit
sensor(config)#
Look for the alerts generated by the signature and look for the IP Log ID
associated with the alert.
Repeat Steps 1 through 15 for other signatures and subsignatures.
You can disable one or all IP logging sessions.
To disable one or all IP logging sessions, follow these steps:
Log in to the CLI using an account with administrator or operator privileges.
To disable a particular IP logging session:
Find the log ID of the session you want to disable by using the iplog-status
a.
command:
sensor# iplog-status
Log ID:
IP Address:
Group:
Status:
Start Time:
Bytes Captured:
Packets Captured:
b.
Disable the IP log session:
sensor# no iplog 137857512
To disable all IP logging sessions:
sensor# no iplog
sensor#
137857512
10.16.0.0
0
started
1070363599443768000
30650
263
Sensor Configuration Tasks