NM-CIDS Configuration Tasks
Step 1
Step 2
Step 3
Step 4
Step 5

Using Telnet

Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
10-82
To close on open session to the NM-CIDS, follow these steps:
Exit the session:
sensor# exit
Suspend and close the session to the NM-CIDS by holding CTRL-Shift and
pressing 6. Release all keys, and then press x.
Disconnect from the router:
Router# disconnect
Press Enter to confirm the disconnection:
Router# Closing connection to 10.16.0.0 [confirm] <Enter>
Exit the session:
Router# exit
You can also telnet directly into the router with the port number corresponding to
the NM-CIDS slot. Use the address you established when configuring the
loopback 0 interface in
page
10-78.
The port number is determined by the following formula: 2001 + 32 x slot number.
For example, for slot 1, the port number is 2033, for slot 2, it is 2065, and so forth.
To use Telnet to invoke a session to port 2033:
Router# telnet 10.16.0.0 2033
Chapter 10
Configuring Cisco IDS Interfaces on the Router,
Configuring the Sensor Using the CLI
78-15597-02