Sensor Initial Configuration Tasks
After you change the password, the
Step 3
Type
The System Configuration Dialog is displayed.
Note
--- System Configuration Dialog ---
At any point you may enter a question mark '?' for help.
User ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets '[]'.
Current Configuration:
networkParams
ipAddress 10.89.146.110
netmask 255.255.255.0
defaultGateway 10.89.146.254
hostname sensor
telnetOption disabled
accessList ipAddress 10.0.0.0 netmask 255.0.0.0
exit
timeParams
summerTimeParams
active-selection none
exit
exit
service webServer
general
ports 443
exit
exit
Current time: Sat May 15 02:52:09 1993
Press the spacebar to get to the following question:
Step 4
Continue with configuration dialog?[yes]:
Press the spacebar to show one page at a time. Press Enter to show one line at a
time.
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
10-4
to initialize the sensor.
setup
The System Configuration Dialog is an interactive dialog. The default
settings are displayed.
Chapter 10
Configuring the Sensor Using the CLI
prompt appears.
sensor#
78-15597-02