Chapter 8
Installing the IDSM-2
Removing the IDSM-2
Warning
Caution
Warning
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Mod Online Diag Status
--- -------------------
1 Pass
2 Pass
5 Pass
6 Not Supported
7 Not Supported
9 Pass
router#
It is normal for the status to read "other" when the IDSM-2 is first
Note
installed. After the IDSM-2 completes the diagnostics routines and comes
online, the status reads "ok." Allow up to 5 minutes for the IDSM-2 to
come online.
See
Enabling a Full Memory Test, page
memory test after verifying the IDSM-2 installation.
This procedure describes how to remove the IDSM-2 from the Catalyst 6500
series switch.
Only trained and qualified personnel should be allowed to install, replace, or
service this equipment. Statement 1030
Before removing the IDSM-2, be sure to perform the shutdown procedure. If the
IDSM-2 is not shut down correctly, you could corrupt the software.
During this procedure, wear grounding wrist straps to avoid ESD damage to the
card. Do not touch the backplane with your hand or any metal tool, or you could
shock yourself.
Installation and Removal Instructions
10-99, for information on enabling a full
8-13