Rebooting The Nm-Cids - Cisco IDS-4230-FE - Intrusion Detection Sys Fast Ethernet Sensor Installation And Configuration Manual

Intrusion detection system appliance and module
Table of Contents

Advertisement

Chapter 10
Configuring the Sensor Using the CLI

Rebooting the NM-CIDS

Caution
Caution
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
The Cisco IOS provides the following commands to control the NM-CIDS:
shutdown, reload, and reset:
shutdown—Brings the operating system down gracefully:
Router# service-module ids-sensor slot_number/0 shutdown
Make sure you execute a shutdown command before you remove the hard-disk
drive from the NM-CIDS. Failing to do so can lead to the loss of data or the
corruption of the hard-disk drive.
reload—Performs a graceful halt and reboot of the operating system on an
NM-CIDS:
Router# service-module ids-sensor slot_number/0 reload
reset—Resets the hardware on the NM-CIDS. Typically this command is used
to recover from a shutdown.
Router# service-module ids-sensor slot_number/0 reset
The following warning appears:
Router# service-module ids-sensor 1/0 reset
Use reset only to recover from shutdown or failed state
Warning: May lose data on the hard disc!
Do you want to reset?[confirm]
Hard-disk drive data loss only occurs if you issue the reset command without first
shutting down the NM-CIDS. You can use the reset command safely in other
situations.