Sensor Configuration Tasks
Step 11
Step 12
Configuring the Sensor to Manager a Catalyst 6500 Series Switch
Step 1
Step 2
Step 3
Step 4
Step 5
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
10-70
Exit shun interfaces submode:
sensor(config-NetworkAccess-rou-shu)# exit
sensor(config-NetworkAccess-rou)# exit
sensor(config-NetworkAccess)# exit
sensor(config)# exit
Apply Changes:?[yes]:
You receive an error if the logical device name does not exist.
Note
Type yes to apply changes.
To configure the sensor to manage a Catalyst 6500 series switch, follow these
steps:
Log in to the CLI using an account with administrator privileges.
Enter configuration mode:
sensor# configure terminal
Enter network access mode:
sensor(config)# service networkAccess
Set the IP address for the router controlled by NAC:
sensor(config-NetworkAccess)# cat6k-devices ip-address
Type the logical device name that you created in
page
10-66.
sensor(config-NetworkAccess-cat)# shun-device-cfg
NAC accepts anything you type. It does not check to see if the logical device
exists.
Designate the method used to access the sensor:
sensor(config-NetworkAccess-cat)# communication
If unspecified, SSH 3DES is used.
Chapter 10
Configuring the Sensor Using the CLI
Configuring Logical Devices,
logical_device_name
telnet/ssh-des/ssh-3des
ip_address
78-15597-02