AS Ser ies Pro gra mm in g M anu al
After power-on, the module allocation of the above example is as shown below.
SR1559 = 2; SR1560 = 4
The order number is counted by the right-side modules connected to the CPU module and then counted by the RTU
number.
SR number (order)
_2
Device code
SR number (order)
Device code
If RTU is disconnected, after reconnected, the system refreshes the SR.
SR1559 = 1; SR1560 = 4
23. Auto-reset flags for pulse output
While executing the pulse output instructions, to avoid the control over the same pulse output device is taken
repeatedly by different type or diffent triggered output instrucitons. PLC auto-reset the right to control the
pulse instruction to the first executed instruction till the assigned instruction is completely stopped. Because
of the unique characteristic, PLC scan cannot detect if the pulse instruction is stopped when you use the
pulse output instruction in the ST language, interrupt subroutine or one-time function block. Therefore, the
right to control the pulse instruction is kept and any ongoing instructions can neither be executed nor
outputted normally.
To free the right to execute other pulse output instructions, you can use the auto-reset flags for the PLC to
check if the output is complete.
Note: you can set the auto-reset flags to ON and once the output is complete, the flag resets to OFF
automatically.
Even number axis for output
Auto-reset when the output is
complete.
Odd number axis for output
Auto-reset when the output is
complete.
2 - 1 5 0
SR1651 (#1)
SR1652 (#2)
16#0309
16#0311
SR1656 (#6)
SR1657 (#7)
16#0315
16#0302
Y0.0
SM470
Y0.1
SM475
SR1653 (#3)
SR1654 (#4)
16#0212
16#0212
SR1658 (#8)
SR1659 (#9)
16#0210
16#0210
Y0.2
Y0.4
Y0.6
SM490
SM510
SM530
Y0.3
Y0.5
Y0.7
SM495
SM515
SM535
SR1655 (#5)
16#0301
Y0.8
Y0.10
SM550
SM570
Y0.9
Y0.11
SM555
SM575