Delta AS Series Programming Manual page 94

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Special auxiliary
relay
SM569–SM569
You set the flag to ON or OFF.
SM572
The system sets the flag to ON or OFF.
SM573
The system sets the flag to ON and you reset it to OFF.
SM574
You set the flag to ON or OFF.
SM578–SM579
You set the flag to ON or OFF and the system sets the flag to OFF.
You set the flag to ON and the system resets it to OFF.
SM580
ON: disable high-speed output
SM585
You set the flag to ON or OFF and the system sets the flag to OFF.
SM586--SM587
You set the flag to ON or OFF.
The system automatically sets the flag to ON and resets it to OFF.
SM600–SM602
The flag is refreshed when the instruction is executed.
SM603
Execute XCMP instruction.
You set SM604 to ON and reset it to OFF.
SM604
ON: sort in descending order
OFF: sort in ascending order
SM605
You set SM605 to ON and reset it to OFF.
You set SM606 to ON and reset it to OFF.
SM606
ON: 8-bit mode
OFF: 16-bit mode
SM607
You set the flag to ON or OFF.
The flag is refreshed when the instruction is executed.
SM608
SM609
You set the flag to ON or OFF.
SM610–SM611
The flag is refreshed when the instruction is executed.
SM612–SM613
You set the flag to ON or OFF.
The flag is refreshed when the instruction is executed.
SM614
SM615–SM617
You set the flag to ON or OFF.
SM618
The flag is refreshed when the instruction is executed.
SM619
The flag is refreshed when the EI or DI instruction is executed.
SM620
The flag is refreshed when the CMPT instruction is executed.
SM621–SM686
You set the flag to ON or OFF.
SM687
The flag is refreshed when the RAMP instruction is executed.
SM688
The flag is refreshed when the INCD instruction is executed.
SM690–SM691
You set the flag to ON or OFF.
SM692
The flag is refreshed when the HKY instruction is executed.
SM693
The flag is refreshed when the SEGL instruction is executed.
SM694
The flag is refreshed when the DSW instruction is executed.
SM695
You set the flag to ON or OFF.
SM749
The system is refreshed at power-on after the data exchange parameters are downloaded.
SM750–SM783
After the data exchange parameters are downloaded, you set the flag to ON or OFF.
SM784–SM847
The flag is ON when the system is refreshed.
SM861
The system is refreshed at power-on after the data exchange parameters are downloaded.
SM862–SM895
After the parameters of data exchange are downloaded, you set the flag to ON or OFF.
SM896–SM959
The flag is ON, when the system is refreshed automatically.
SM976-SM990
The flag is ON, when the system is refreshed automatically.
SM1000
You set the flag to ON and after saving, the system sets the flag to OFF.
SM1006
You set the flag to ON or OFF.
Refresh time
Cha p ter 2 De vices
2 - 7 1
2_

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents