Delta AS Series Programming Manual page 89

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

AS Ser ies Pro gra mm in g M anu al
Special auxiliary
relay
SM76–SM77
SM78–SM79
_2
SM80–SM81
SM82–SM83
SM84–SM85
SM86–SM87
SM90–SM91
SM94–SM95
SM96–SM97
SM98–SM99
SM100–SM101
SM102–SM103
SM104–SM105
SM106–SM107
SM120-SM151
SM166–SM167
SM168–SM171
SM203
SM204–SM205
SM206
SM209
SM210
SM211
SM212
SM215
2 - 6 6
to OFF automatically. You set it to ON to enable saving.
ON: the system executes the communication task. After the communication task is complete, the
system resets it to OFF automatically. You set it to ON to enable execution.
ON: communication is in progress. After the communication is complete, the system resets it to
OFF automatically.
ON: reception is complete. You reset it to OFF.
ON: an error occurs in the response. You reset it to OFF.
ON: a timeout occurs. You reset it to OFF.
You set the flag to ON and reset it to OFF.
ON: 8-bit mode
OFF: 16-bit mode
You set the flag to ON. After the communication protocol is changed, the system resets it to
OFF.
After power-on, the flag is ON or OFF according to the settings in HWCONFIG. You can change
this setting.
You set the flag to ON. After the data is sent, the system automatically resets the flag to OFF.
ON: communication is in process. After the communication is complete, the system resets it to
OFF automatically.
The system automatically sets the flag to ON, and you reset it to OFF.
ON: the command is received.
The system automatically sets the flag to ON, and you reset it to OFF.
ON: the command received is wrong.
The system automatically sets the flag to ON, and you reset it to OFF.
ON: there is a receive timeout.
You set the flag to ON and reset it to OFF.
ON: 8-bit mode
OFF: 16-bit mode
You set the flag to ON and while executing DPLSY instruction, the system resets it to OFF.
You set the flag to ON and reset it to OFF.
The system automatically sets the flag to ON, and resets it to OFF.
You set the flag to ON and after PLC RUN->STOP, it clears the non-latched area. The system
automatically resets the flag to OFF.
You set the flag to ON, and the system automatically resets it to OFF.
ON: clear the non-latched/latched areas.
You set SM206 to ON and reset it to OFF.
ON: inhibit all output.
You set SM209 to ON, and the system automatically resets it to OFF.
ON: the communication protocol of COM1 changes.
You set SM210 to ON and reset it to OFF for COM1.
ON: RTU mode
OFF: ASCII mode
You set SM211 to ON, and the system automatically resets it to OFF.
ON: the communication protocol of COM2 changes.
You set SM210 to ON and reset it to OFF for COM2.
ON: RTU mode
OFF: ASCII mode
You set SM215 to ON and reset it to OFF.
ON: the PLC runs.
Refresh time