AS Ser ies Pro gra mm in g M anu al
Backup file with password
Backup file without password
_2
 SR36 only stores 2 logs:
A.
The number 1234 means the PLC stores the error log (SR40–SR161) in the memory card.
B. The number 3456 means the PLC stores the error log (SR40–SR161) and the PLC state changing log
(SR309–SR390) in the memory card.
13. The high-speed output instruction is being executed. The output immediately stops when the instruction is
disabled or stops.
 SM587: while using the position planning table to control the output, the axis should refer to the following flags
for the action to stop. This function is available for firmware V.1.06.00 or later.
 SM476, SM477, SM496, SM497, SM516, SM517, SM536, SM537, SM556, SM557, SM576, SM577:
OFF (default): deceleration stop
ON: immediate stop
 SM463, SM474, SM483, SM494, SM503, SM514, SM523, SM534, SM543, SM554, SM563, SM574:use these
flags to pause output.
When the flag changes from OFF to ON, it means stop the output. This works with these flags; refer to the
section above for more actions on stop.
When the flag changes from ON to OFF, it means execute the rest of the outputs.
 The flag for position output axis 1-6 (even number high speed pulse output points) in ramp up / ramp down area
is available for firmware V1.06.00 or later.
 SM586
OFF (default): use high-intensity 250 steps to switch to different speeds in the ramp up/ramp down area and the
error rate of switching time is about 10%.
ON:use high-intensity 25 steps to switch to different speeds in the ramp up/ramp down area and the error rate of
switching time is about 1%.
14. Position control output limit in ISPSoft
 SR580-SR603
Positive output limit: set the limit in ISPSoft. When the output position is greater than the positive limit, the output
stops immediately.
Negative output limit: set the limit in ISPSoft. When the output position is smaller than the negative limit, the output
stops immediately.
When the positive and negative output limits are both 0, the function is disabled. This function works with the
output instructions. The system only checks the limit set in ISPSoft when the instruction is executed. Thus the
system does not come to an immediate stop even when it is beyond the output limit. If an immediate stop is
needed, using the external input as the way to check the limit is recommended.
2 - 1 3 8
CPU module with password
Password matched: restoring
Password not matched: not
restoring
Not restoring
CPU module without password
Restoring and you can also set the
CPU module with password
Restoring