Delta CFP2000 Series User Manual page 630

Ip55 fan and pump drive
Table of Contents

Advertisement

API
FEND
06
Bit device
X
Y
M
K
Notes on operand usage:
No operand
A contact-driven command is not needed
Word device
H
KnX KnY KnM
T
This command indicates the end of the main program. It is the same as
the END command when the PLC executes this command.
The CALL command program must be written after the FEND command,
and the SRET command added to the end of the subprogram.
When using the FEND command, an END command is also needed.
However, the END command must be placed at the end, after the main
program and subprogram.
16-57
Chapter 16 PLC Function Applications│CFP2000
Conclusion a main program
16-bit command (1 STEP)
Continuous
C
D
FEND
execution type
32-bit command
Flag signal: none