Chapter 12 Description of Parameter SettingsCFP2000
These parameters record the operation time for Motor 1 to Motor 8. For examples, Pr.12-10 and
Pr.12-11 both record the operation time for Motor 1. Pr.12-10 records the operation time in
minutes and seconds, whereas Pr.12-11 records the operation time in hours. When Pr.12-10
displays 5959, it means the motor has operated for 59 minutes and 59 seconds. When the motor
operates for an hour, Pr.12-11 displays 1 and Pr.12-10 displays 0.
When circulation control Pr.12-00=1–5, the output frequency is > 0 Hz and output current is > 0
A, the motor operation time is recorded.
When the record reaches the upper limit 65535 hours 59 minutes and 59 seconds, clear the
motor operation time manually to keep tracking the operation status of each motor, and the
service life of the motor.
Motor No. /
Motor Operation Time
Motor 1
Motor 2
Motor 3
Motor 4
Motor 5
Motor 6
Motor 7
Motor 8
All motors
Clear Motor's Operation Time
Settings 0: No function
Clear the operation time for single motor or all motors as needed.
1: The operation time for Motor 1 returns to zero, including operation records in Pr.12-11 (hour)
and Pr.12-10 (min. /sec.).
10: The operation time for Motor 1–8 (Pr.12-10–Pr.12-25) all return to zero.
Hour
Pr.12-11 = 65535
↓
65535 hour
Pr.12-13
Pr.12-15
Pr.12-17
Pr.12-19
Pr.12-21
Pr.12-23
Pr.12-25
N/A
1: Clear operation time for motor 1
2: Clear operation time for motor 2
3: Clear operation time for motor 3
4: Clear operation time for motor 4
5: Clear operation time for motor 5
6: Clear operation time for motor 6
7: Clear operation time for motor 7
8: Clear operation time for motor 8
10: Clear operation time for all motors
Min./Sec.
Pr.12-10 = 5959
↓
59 min.: 59 sec.
Pr.12-12
Pr.12-14
Pr.12-16
Pr.12-18
Pr.12-20
Pr.12-22
Pr.12-24
N/A
12.1-12-18
Clear
Motor Operation Time
Pr.12-26=1
Pr.12-26=2
Pr.12-26=3
Pr.12-26=4
Pr.12-26=5
Pr.12-26=6
Pr.12-26=7
Pr.12-26=8
Pr.12-26=10
Default: 0