Delta CFP2000 Series User Manual page 638

Ip55 fan and pump drive
Table of Contents

Advertisement

API
BIN
19
D
P
Bit device
X
Y
M
K
S
D
Notes on operand usage: none
S
: Data source.
The content of data source
and saves in
Valid number range of the data source S: BCD (0–9,999), DBCD (0–99,999,999).
When X0 is ON, and the BCD value of K1X20 is transformed to BIN value, the
result saves in D10.
X0
When PLC reads a BCD type switch-off from the outside, it has to use the BIN
command to transform the read data to BIN value, then saves the value into PLC.
S
D
Word device
H
KnX KnY KnM
T
D
: Transformation result.
D
.
BIN
K1X20
Chapter 16 PLC Function Applications│CFP2000
BCD to BIN transformation
16-bit command (5 STEP)
BIN
Continuous
C
D
execution type
32-bit command (9 STEP)
DBIN
Continuous
execution type
Flag signal: none
S
(BCD: 0–9,999) executes BIN transformation
D10
16-65
BINP
Pulse
execution type
DBINP
Pulse
execution type