Other Communication Card Speed Setting (for DeviceNet)
Settings
 Use with Pr.09-71.
 Setting 0: The baud rate can only be set to 125 Kbps, 250 Kbps and 500 Kbps.
 Setting 1: The DeviceNet communication rate can be the same as that for CANopen (setting
0–8).
Communication Card IP Configuration (for Modbus TCP)
Settings
 Setting 0: Set the IP address manually.
 Setting 1: IP address is automatically set by the host controller.
Communication Card IP Address 1 (for Modbus TCP)
Communication Card IP Address 2 (for Modbus TCP)
Communication Card IP Address 3 (for Modbus TCP)
Communication Card IP Address 4 (for Modbus TCP)
Settings
 Use Pr.09-76–09-79 with a communication card.
Communication Card Address Mask 1 (for Modbus TCP)
Communication Card Address Mask 2 (for Modbus TCP)
Communication Card Address Mask 3 (for Modbus TCP)
Communication Card Address Mask 4 (for Modbus TCP)
Settings
Communication Card Gateway Address 1 (for Modbus TCP)
Communication Card Gateway Address 2 (for Modbus TCP)
Communication Card Gateway Address 3 (for Modbus TCP)
4: 125 Kbps
5: 250 Kbps
6: 500 Kbps
7: 800 Kbps
8: 1 Mbps
0: Standard DeviceNet
In this mode, the baud rate can only be 125 Kbps, 250 Kbps, and 500 Kbps
in standard DeviceNet speed.
1: Nonstandard DeviceNet
In this mode, the baud rate of DeviceNet can be the same as that for
CANopen (0–8).
0: Static IP
1: DynamicIP (DHCP)
0–65535
0–65535
12.1-09-17
Chapter 12 Description of Parameter SettingsCFP2000
Default: 0
Default: 0
Default: 0
Default: 0