activated. At this time, if you want to change any parameter settings, you must enter the correct
password in Pr.00-07 to deactivate the password temporarily, and this would make Pr.00-08
become 0. After you finish setting the parameters, reboot the motor drive and the password is
activated again.
 Entering the correct password in Pr.00-07 only temporarily deactivates the password. To
permanently deactivate password protection, set Pr.00-08 to 0 manually. Otherwise, password
protection is always reactivated after you reboot the motor drive.
 The keypad copy function works only when the password protection is deactivated (temporarily or
permanently), and the password set in Pr.00-08 cannot be copied to the keypad. So when
copying parameters from the keypad to the motor drive, set the password manually again to
activate password protection.
Password Decode Flow Chart
Speed Control Mode
Settings
 Determines the control method of the AC motor drive:
0: IM V/F control: you can set the proportion of V/F as required and control multiple motors
simultaneously.
2: IM / PM space vector control: get the optimal control by auto-tuning the motor parameters.
0: IMVF (IM V/F control)
2: IM / PM SVC (IM / PM space vector control)
12.1-00-5
Chapter 12 Description of Parameter SettingsCFP2000
Default: 0