Pr.
Parameter Name
02-09
UP / DOWN key mode
Constant speed, acceleration /
02-10
deceleration speed of the UP /
DOWN key
02-11
Multi-function input response time
02-12
Multi-function input mode selection
02-13
Multi-function output 1 RLY1
02-14
Multi-function output 2 RLY2
02-15
Multi-function output 3 RLY3
Output terminal of the I/O extension
02-36
card (MO10) or (RA10)
Output terminal of I/O extension card
02-37
(MO11) or (RA11)
Output terminal of I/O extension card
02-38
(RA12)
Output terminal of I/O extension card
02-39
(RA13)
Output terminal of I/O extension card
02-40
(RA14)
Output terminal of I/O extension card
02-41
(RA15)
Output terminal of I/O extension card
02-42
(MO16 virtual terminal)
Output terminal of I/O extension card
02-43
(MO17 virtual terminal)
Output terminal of I/O extension card
02-44
(MO18 virtual terminal)
Output terminal of I/O extension card
02-45
(MO19 virtual terminal)
Output terminal of I/O extension card
02-46
(MO20 virtual terminal)
Chapter 11 Summary of Parameter SettingsCFP2000
Setting Range
56: Local / Remote selection
58: Enable fire mode (with RUN command)
59: Enable fire mode (without RUN command)
60: Disable all the motors
61: Disable Motor 1
62: Disable Motor 2
63: Disable Motor 3
64: Disable Motor 4
65: Disable Motor 5
66: Disable Motor 6
67: Disable Motor 7
68: Disable Motor 8
69: Preheating command
0: UP / DOWN by acceleration / deceleration time
1: UP / DOWN constant speed (Pr.02-10)
0.001–1.000 Hz / ms
0.000–30.000 sec.
0000h–FFFFh (0: N.O.; 1: N.C.)
0: No function
1: Indication during RUN
2: Operation speed reached
3: Desired frequency reached 1 (Pr.02-22)
4: Desired frequency reached 2 (Pr.02-24)
5: Zero speed (Frequency command)
6: Zero speed including STOP (Frequency
command)
7: Over-torque 1 (Pr.06-06–06-08)
8: Over-torque 2 (Pr.06-09–06-11)
9: Drive is ready
10: Low voltage warning (Lv) (Pr.06-00)
11: Malfunction indication
12: Mechanical brake release (Pr.02-32)
13: Over-heat warning (Pr.06-15)
14: Software brake signal indication (Pr.07-00)
15: PID feedback error (Pr.08-13, Pr.08-14)
16: Slip error (oSL)
17: Count value reached, does not return to 0
(Pr.02-20)
18: Count value reached, returns to 0
(Pr.02-19)
19: External interrupt B.B. input (Base Block)
20: Warning output
21: Over-voltage
22: Over-current stall prevention
23: Over-voltage stall prevention
24: Operation mode